| Product Number | ARXP1103 |
|---|---|
| Product Number | ARXP1103 |
| Product Name | RX-P Relays(Discontinued) |
| Features | 3GHz Microwave Relay With 60W carrying power |
Spec Detail
| Item | Specifications |
|---|---|
| Part Number | ARXP1103 |
| Product Number | ARXP1103 |
| Operating function | 1 Coil Latching Type |
| Terminal shape | Standard PC board terminal |
| Frequency | 2.5GHz |
| V.S.W.R | Max. 1.2 |
| Insertion loss | Max. 0.2dB |
| Isolation | Min. 60dB |
| Impedance | 50Ω |
| Rated coil voltage | 3V DC |
| Set voltage (at 20 ℃) | Max. 75 % V of rated coil voltage (Initial) |
| Reset voltage (at 20 ℃) | Max. 75 % V of rated coil voltage (Initial) |
| Rated operating power | 200mW |
| Contact arrangement | 1 Form C |
| Contact material | Stationary: Au plating, Movable: Au clad |
| Contact rating | 40W (at 2.5 GHz, 50Ω, V.S.W.R. Max. 1.2) |
| Dielectric strength Between open contacts (initial) | 500 V rms for 1 min (detection current: 10 mA) |
| Dielectric strength Between contact and coil (initial) | 1,000 V rms for 1 min (detection current: 10 mA) |
| Expected mechanical life (cold switch) | Min. 10x103 ope. (switching frequency: at 180 times/min) |
| Expected electrical life (hot switch) | Min. 10x103 ope. (switching frequency: at 20 times/min) 40W (2.5 GHz, 50Ω, V.S.W.R. Max. 1.2) |
| Conditions | Ambient temperature: -40 to +70 ℃ Humidity: 5 to 85% RH (Avoid icing and condensation) |