| Product Number | ADQ13Q04H |
|---|---|
| Product Number | ADQ13Q04H |
| Product Name | DQ Relays(Discontinued) |
| Features | 1 Form A 30A power latching relays |
Spec Detail
| Item | Specifications |
|---|---|
| Part Number | ADQ13Q04H |
| Product Number | ADQ13Q04H |
| Protective construction | Sealed |
| Operating function | 1 coil latching |
| Terminal shape | Tab terminal |
| Standard packing Carton (pieces) | 20 |
| Standard packing Case (pieces) | 200 |
Coil data
| Item | Specifications |
|---|---|
| Rated coil voltage | 4.5 V DC |
| Set voltage (at20℃) | Max. 70% V of rated coil voltage (Initial) |
| Reset voltage (at20℃) | Max. 70% V of rated coil voltage (Initial) |
| Rated operating current [±10%] (at 20℃) | 111.1 mA |
| Coil resistance [±10%] (at 20℃) | 40.5 Ω |
| Rated operating power | 500 mW |
| Max. allowable voltage (at 20℃) | 130% V of rated coil voltage |
Specifications
| Item | Specifications |
|---|---|
| Contact arrangement | 1 Form A |
| Contact shape | Single |
| Contact specification | Standard contact |
| Contact resistance (initial) | Max. 30 mΩ (by voltage drop 6 V DC 1 A) |
| Contact material | AgSnO2 type |
| Contact rating (resistive load) | 30 A 250 V AC |
| Max. switching power (resistive load) | 7,500 VA |
| Max. switching voltage | 250 V AC |
| Max. switching current | 30 A (AC) |
| Min. switching load (reference value) | 100 mA 5 V DC |
| Insulation resistance (initial) | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) |
| Dielectric strength (initial) : Between open contacts | 1,500 Vrms for 1 min (detection current: 10 mA) |
| Dielectric strength (initial) : Between contact and coil | 4,000 Vrms for 1 min (detection current: 10 mA) |
| Surge withstand voltage (initial) : Between contact and coil | 10,000 V |
| Set time (Initial) (at 20℃) | Max. 20 ms at rated coil voltage (without bounce) |
| Reset time (Initial) (at20℃) | Max. 20 ms at rated coil voltage (without bounce) |
| Shock resistance (Functional) (initial) | 200 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs) |
| Shock resistance (Destructive) (initial) | 1,000 m/s2 (half-sine shock pulse: 6 ms) |
| Vibration resistance (Functional)(initial) | 10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 μs) |
| Vibration resistance (Destructive)(initial) | 10 to 55 Hz (at double amplitude of 2 mm) |
| Mechanical life | Min. 106 ope. (switching frequency: at 180 times/min) |
| Conditions | Ambient temperature: -40 to +65℃ Humidity: 5 to 75% RH (Avoid icing and condensation) |
| Unit weight | Approx. 35 g |
Expected electrical life
| Item | Specifications |
|---|---|
| Resistive load | [switching frequency ON : OFF = 3 s : 3 s] Min. 10x103 ope. 30 A 250 V AC |
Information on Compliance with Standards
| Status | Status | Information on Compliance | ||
|---|---|---|---|---|
| UL/C-UL | Approval | File No. | E43149 | |
| Rating | 30A 277V AC | |||
| Remarks | - | |||
| Last update | ||||
| CSA | N/A | File No. | - | |
| Rating | - | |||
| Remarks | CSA standard certified by C-UL | |||
| Last update | ||||
| Mark on products* | ||||
* The "Mark on products" field shows the standards' certificate type marked to products. Note that not all certified products have a certificate mark affixed to them.