ADZS22105|DZ-S Relays
Download
To Be Discontinued
Discontinued
*Photo may vary from actual product.
This product has been confirmed that it does not contain the 6 substances specified in EU RoHS Directive 2011/65/EU and the 4 substances specified in 2015/863/EU.
| Product Number | ADZS22105 |
|---|---|
| Product Number | ADZS22105 |
| FAQ | Not Recommended for New Design (NRFND) Notification |
| Product Name | DZ-S Relays |
| Features | IEC62055-31 UC3 compliant, 1 Form A 90 A, Power latching relays |
*Specifications and design of the products are subject to change without notice for the product improvement.
Spec Detail
Specifications and design of the products are subject to change without notice for the product improvement.
| Item | Specifications |
|---|---|
| Part Number | ADZS22105 |
| Product Number | ADZS22105 |
| Protective construction | Dust Cover |
| Operating function | 2 coil latching |
| Terminal shape | Vertical terminal |
| Contact rating type | High switching capacity |
| Standard packing Carton (pieces) | 20 |
| Standard packing Case (pieces) | 200 |
Coil data
| Item | Specifications |
|---|---|
| Rated coil voltage | 5 V DC |
| Set voltage (at20℃) | Max. 70% V of rated coil voltage (Initial) |
| Reset voltage (at20℃) | Max. 70% V of rated coil voltage (Initial) |
| Rated operating current [±10%] (at 20℃) | 600 mA |
| Coil resistance [±10%] (at 20℃) | 8.3 Ω |
| Rated operating power | 3.0 W |
| Max. allowable voltage (at 20℃) | 130% V of rated coil voltage |
Specifications
| Item | Specifications |
|---|---|
| Contact arrangement | 1 Form A |
| Contact shape | Single |
| Contact voltage drop (Initial) | Max. 0.09 V (at 90 A), Max. 0.05 V (at 10 A) |
| Contact material | AgSnO2 type |
| Contact rating (resistive load) | 90 A 250 V AC |
| Max. switching power (resistive load) | 24,840 VA |
| Max. switching voltage | 276 V AC |
| Max. switching current | 90 A (AC) |
| Min. switching load (reference value) | 100 mA 125 V AC |
| Insulation resistance (initial) | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) |
| Dielectric strength (initial) : Between open contacts | 2,000 Vrms for 1 min (detection current: 10 mA) |
| Dielectric strength (initial) : Between contact and coil | 4,000 Vrms for 1 min (detection current: 10 mA) |
| Surge withstand voltage (initial) : Between contact and coil | 12,000 V |
| Set time (Initial) (at 20℃) | Max. 20 ms at rated coil voltage (without bounce) |
| Reset time (Initial) (at20℃) | Max. 20 ms at rated coil voltage (without bounce) |
| Shock resistance (Functional) (initial) | 300 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs) |
| Shock resistance (Destructive) (initial) | 1,000 m/s2 (half-sine shock pulse: 6 ms) |
| Vibration resistance (Functional)(initial) | 10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 μs) |
| Vibration resistance (Destructive)(initial) | 10 to 55 Hz (at double amplitude of 2 mm) |
| Mechanical life | Min. 100x103 ope. (switching frequency: at 180 times/min) |
| Conditions | Ambient temperature: -40 to +85℃ Humidity: 5 to 85% RH (Avoid icing and condensation) |
| Unit weight | Approx. 45 g |
Expected electrical life
| Item | Specifications |
|---|---|
| Resistive load | [switching frequency: at 20 times/min (ON : OFF = 2 s : 4 s)] Min. 10x103 ope. 90 A 250 V AC |
Electrical life
| Item | Specifications |
|---|---|
| UC3 Class (IEC62055-31) | [switching frequency ON : OFF = 10 s : 20 s] Min. 10x103 ope. 90 A 276 V AC (cosΦ = 1 : 5,000 cycles, cosΦ = 0.5 : 5,000 cycles) |