Panasonic Industry / Automation Controls
Panasonic Industry / Automation Controls

KT4 Temperature Controllers (Discontinued Products)

  • Discontinued Products

  • Rating/ Performance

  • Dimensions

  • Wiring/ Connection

  • Cautions For Use

Ⅾiscontinued

Last time buy (JST)

September 29, 2023

We are sorry, the products have been discontinued. Please refer to the details of the discontinued products and the recommended substitutes list below.

Discontinued Products

pic01

Rating/ Performance

Rating And Specifications

DisplaySpecifications
KT4
Size48×48mm
RatingSupply voltage (Must be specified)100 to 240V AC
24V AC/DC
Frequency50/60Hz
Power consumptionApprox. 8VA
Rated scaleInput typeInput range
ThermocoupleK-200 to 1370°C(-320 to 2500 ℉)
-199.9 to 400.0°C(-199.9 to 750.0 ℉)
J-200 to 1000°C(-320 to 1800 ℉)
R0 to 1760°C(0 to 3200 ℉)
S0 to 1760°C(0 to 3200 ℉)
B0 to 1820°C(0 to 3300 ℉)
E-200 to 800°C(-320 to 1500 ℉)
T-199.9 to 400.0°C(-199.9 to 750.0 ℉)
N-200 to 1300°C(-320 to 2300 ℉)
PL-II0 to 1390°C(0 to 2500 ℉)
C(W/Re5-26)0 to 2315°C(0 to 4200 ℉)
RTDPt100-200 to 850°C(-300 to 1500 ℉)
-199.9 to 850.0°C(199.9 to 999.9 ℉)
JPt100-200 to 500°C(-300 to 900 ℉)
-199.9 to 500.0°C(-199.9 to 900.0 ℉)
DC Current4 to 20mA DC-1999 to 9999, -199.9 to 999.9 -19.99 to 99.99, -1.999 to 9.999
0 to 20mA DC
DC Voltage0 to 1V DC
0 to 10V DC
1 to 5V DC
0 to 5V DC
 · Scaling and change to the decimal point position is possible for DC current and DC voltage input.
· DC current input is supported with an externally mounted 50Ω shunt resistor (sold separately).
Multi-inputThermocoupleK, J, R, S, B, E, T, N, PL-II, C (W/Re5-26)
External resistor: Max. 100Ω (max. 40Ω external resistor for B input)
RTDPT100, JPt100 3-conductor system (Allowable input conductor resistance for each conductor: max. 10Ω)
DC current0 to 20 mA DC, 4 to 20 mA DC
Input impedance: 50Ω (Connect 50Ω shunt resistor between input terminals.)
Allowable input current: max. 50 mA (when 50Ω shunt resistor is used)
DC voltage· 0 to 1V DC
Input impedance: min. 1 MΩ, Allowable input voltage: max 5 V, Allowable signal source resistance: max. 2 kΩ
· 0 to 5 V DC, 1 to 5 V DC, 0 to 10 V DC
Input impedance: min. 100 kΩ, Allowable input voltage: max 15 V, Allowable signal source resistance: max. 100Ω
Control output
(Must be specified)
Relay contact(contact material:sliver alloy)1a
1a 3A 250V AC (Resistive load),1a 1A 250V AC (Inductive load cosØ=0.4), Electric life: 100,000 times
Non-contact DC voltage12+20 V DC, Max. load current: 40mA (Short-circuit protected)
DC current4 to 20mADC Load resistance: Max. 550Ω
Alarm output 1Relay contact 1a 3A 250VAC (Resistive load)
Electric life: 100,000 times
Alarm output 2The same as the one of Alarm output 1
Control modeActions mentioned below can be selected by key operation.
[Default PID] PID (with auto-tuning function), PI, PD (with manual reset function), P (with manual reset function), ON/OFF action
Target temperature setting-
Program control function-
AccuracyThermocoupleWithin ±0.2% ±1 digit of each input span or within ±2°C (4℉) whichever is greater
However, R and S input; Within ±6°C (12℉) in the range of 0 to 200°C (0 to 400℉)
B input 0 to 300°C (0 to 600℉): Accuracy is not guaranteed.
K, J, E, and N input less than 0°C (32℉): Within ±0.4% ±1 digit of input span
RTDWithin ±0.1% ±1 digit of each input span or ±1°C (2℉) whichever is greater
DC current and DC voltageWithin ±0.2% ±1 digit of each input span
Sampling period250ms
HysteresisThermocouple and RTD: 0.1 to 100.0°C ()
DC current and DC voltage: 1 to 1000 (The decimal point place follows the selection)
Proportional bandThermocouple: 0 to 1000℃ (0 to 2000 ℉) RTD: 0.0 to 999.9℃ (0.0 to 999.9 ℉) DC current and DC voltage: 0.0 to 100.0%
Integral time0 to 1000 seconds
Derivative time0 to 300 seconds
Proportional cycle1 to 120 seconds
Allowable voltage fluctuationWhen 100 to 240V AC; 85 to 264V AC When 24V AC/DC; 20 to 28V AC/DC
Insulated resistance500V DC 10MΩ or greater
Breakdown voltage1.5kV AC for 1min between input terminal and ground terminal,
between input terminal and power terminal
between power terminal and ground terminal
between output terminal and ground terminal, and between output terminal and power terminal
Malfunction vibration10 to 55 Hz (1 cycle/min.), single amplitude: 0.35 mm 0.014 in (10 min. on 3 axes)
Breakdown vibration10 to 55 Hz (1 cycle/min.), single amplitude: 0.75 mm 0.030 in (1 hour on 3 axes)
Malfunction shockX, Y and Z each direction for 5 times 10G
Breakdown shockSame as above, but 30G
Ambient temperature0 to 50°C
Ambient humidity35 to 85%RH (No condensation)
MassApprox. 130g
WaterproofIP66 (applicable only to the front panel subject to rubber gasket employed)
Display character heightPV:10.2mm SV:8.8mm
OptionsHeating/Cooling control
(Relay contact material:silver alloy)
Non contact relay 0.3A 250V AC
(Resistive load)
Heater burn-out alarm output
(Relay contact material:silver alloy)
Heater rated current must be selected from 5A, 10A, 20A and 50A.
Setting accuracy: Within 5% of heater rated current
Relay contact 1a 250V AC 3A (Resistive load), Electric life: 100,000 times
Communication functionRS-485/Modbus Protocol
(Modbus is a communication protocol developed for PLCs by Modicon Inc.)
Communication speed: 2400/4800/9600/19200bps
AccessoriesMounting frameIncluded with unit
Terminal coverSold separatel

Communication Function Overview

ItemSpecification
Communication methodHalf-duplex
Communication speedSelect 2,400, 4,800, 9,600, or 19,200 bps using key operation.
Synchronization typeAsynchronous
ProtocolModbus
CodingASCII
Error correctingParity check and check sum
Error detectionParity check, check sum
Data structureStart bit: 1 Data bit: 7 Parity: Even parity Stop bit: 1
InterfaceEIA RS-485 compliant
No. of nodes31
Maximum cable length1,000 m 3,280.840 ft(cable resistance must be within 50Ω

Dimensions

  • Unit: mm in

KT4 Series

General tolerance :
±1.0
±0.39

KT4

Panel cutout

KT4

Note) The communications terminal is the screw terminal on the back of the unit.

Shunt Resistor

AKT4810

Shunt resistor

Terminal Cover

AKT4801

AKT4801

Current Transformer (CT)

CT1

Current transformer (CT) (for 5, 10, and 20A)

CT2

Current transformer (CT) (for 50 A)

Note:

Current transformer CT1 or CT2 is included (only with KT7 and KT4H)
when heater burnout alarm function is added.

CT1(5, 10, 20A用)
CT1(5, 10, 20A用)
CT2(50A用)
CT2(50A用)

Wiring/ Connection

External Connection Diagram

POWER SUPPLY : Power supply

OUT1 : Control output 1 (heat output)

OUT2 : Control output 2 (cooling output) RELAY : Relay contact output

V/A : DC voltage output/direct current output V : Contactless relay output

A1 : Alarm 1 output EVT : Event output (A2 output and heater cutoff alarm output)

CT : CT input TC : Thermocouple RTD Resistance temperature detector

DC : Direct current or DC voltage

RS-485 : Serial communications

Communication Function Connection Diagram (PLC Connection Diagram)

Wiring/ Connection

EXTERNAL CONNECTION DIAGRAM

EXTERNAL CONNECTION DIAGRAM

PWR : Power supply voltage 100-240 V AC or 24 V AC / DC (Ensure correct polarity when using DC in AC / DC 24 V.)

EV1 : Alarm output 1

EV2 : Alarm output 2 (optional) O1 : Control output 1

TC : Thermocouple input

RTD : Resistance temperature detector input

DC : DC voltage input or DC current input

RS-485 : Serial communication RS-485

COMMUNICATION FUNCTION CONNECTION DIAGRAM (PLC Connection Diagram)

COMMUNICATION FUNCTION CONNECTION DIAGRAM (PLC Connection Diagram)

Note:Terminating resistors (Terminators)The KT series has a built-in pull-up resistor or pull-down resistor, which serves as the terminating resistor.For this reason, do not connect the terminating resistor on the communication line.