Liquid Detection Fiber FD-BEF
Download
-
Basic Information
-
Applications
-
Order guide
-
Specifications
-
Dimensions
-
Cautions For Use
Basic Information
※Actual products may differ from the photos.
Extremely Easy Tube Replacement!
Liquid Detection Fiber for Cell Culture Apparatus
Contact Us
Features
One-touch system for tube replacement
Anyone can easily replace the tube without tools.

Applicable tubes:Silicone and PVC tubes
Liquid Detection Fiber accepts tubes that are commonly used with cell culture apparatus.
| Applicable tubes | |
|---|---|
| Material | Diameter (Outside / Inside) |
| Silicone / PVC | ø4 × 2 mm |
| ø5 × 3 mm | |
| ø6.4 × 3.2 mm (1/4 × 1/8 in) | |
| ø9.5 × 6.4 mm (3/8 × 1/4 in) | |
Selectable tube removal direction
Mounting holes are designed to allow the sensor installation in two different orientations so that the tube removal direction can be selected.

Monitoring for prevention of nonattachment of tube
When the Liquid Detection Fiber is used in combination with the 2-output fiber amplifier (FX-502, FX-502P), the tube / liquid condition can be indicated in three patterns.

* Please refer to the instruction manual for setting method of fiber amplifier. Before use, be sure to verify operation with your actual tube under your application conditions.
Flexible and robust fiber core allows for easy tube routing.
The fiber core withstands bending radius of 2 mm 0.079 in and is flex-resistant.

Applications
Closed-container-type cell culture apparatus

Order guide
Liquid Detection Fiber
* Be sure to use the Liquid Detection Fiber in combination with a fiber amplifier.
Fiber Amplifier
| Type | Appearance | Model No. | Description |
|---|---|---|---|
| FX-500 series | ![]() | FX-501 | Standard (1-output) type <Detection purpose> No liquid sensing |
| FX-501P | |||
![]() | FX-502 | 2-output type <Detection purpose> No liquid sensing (Output 1) and detection of error such as tube nonconnection / disconnection, and power loss (Output 2) | |
| FX-502P |
* For the details of fiber amplifiers, please refer to the FX-500 series digital fiber sensor catalog or visit our website.
Specifications
Type | For ø4 mm tube | For ø5 mm tube | For ø6.4 mm (1/4 in) tube | For ø9.5 mm (3/8 in) tube |
|---|---|---|---|---|
Model No. | FD-BEF40 | FD-BEF50 | FD-BEF64 | FD-BEF95 |
| Applicable amplifier | FX-501, FX-501P, FX-502, FX-502P | |||
| Sensing object | Transparent water or liquid with the same refractive index (Note 1) | |||
| Recommended bending radius | R4 mm R0.157 in (Note 2) | |||
| Fiber cable length | 2 m 6.562 ft | |||
| Ambient temperature | -40 to +70 °C -40 to +158 °F | |||
| Ambient humidity | 35 to 85 % RH | |||
| Material | Tube installation part: Nylon, Sensing part: ABS resin Lens: Polycarbonate | |||
| Accessories | FX-CT2 (Fiber cutter): 1 pc. FX-AT4 (Fiber attachment for ø1 mm ø0.039 in): 1 pc. | |||
Notes:
1) It may not be possible to sense cloudy liquid, liquid with different refractive index, or liquid with high viscosity (liquid that causes the light to disperse).
2) Due to variations in the fiber amplifier's displayed values, a bending radius of R4 mm or more is recommended.
Applicable tubes
| Type | For ø4 mm tube | For ø5 mm tube | For ø6.4 mm (1/4 in) tube | For ø9.5 mm (3/8 in) tube | ||
|---|---|---|---|---|---|---|
| Model No. | FD-BEF40 | FD-BEF50 | FD-BEF64 | FD-BEF95 | ||
| Applicable tube | Material | Clear / transparent flexible tube (flexible polyvinyl chloride and silicone) | ||||
| Diameter (Note 3) | Outside | 4 mm | 5 mm | 6.4 mm (1/4 in) | 9.5 mm (3/8 in) | |
| Inside | 2 mm | 3 mm | 3.2 mm (1/8 in) | 6.4 mm (1/4 in) | ||
| Conformity confirmed tube (Note 4) | Silicone | 3355L | Sani-Tech Ultra | |||
| PVC | LMT-55 | |||||
Notes:
3) With respect to tubes that are outside the specified diameter or wall thickness, no guarantee can be given for the sensing performance. There is a risk of damage.
4) Tubes manufactured by Saint-Gobain K.K. When using different tubes, be sure to check them with the actual product.
Dimensions
Unit: mm in
FD-BEF□
Free-cut
<with FX-AT4>

| Model No. | A | B | C |
|---|---|---|---|
| FD-BEF40 | ø3.9 mm ø0.154 in | 4.05 mm 0.159 in | 18.75 mm 0.738 in |
| FD-BEF50 | ø4.9 mm ø0.193 in | 4.55 mm 0.179 in | 19.25 mm 0.758 in |
| FD-BEF64 | ø5.9 mm ø0.232 in | 5.1 mm 0.201 in | 19.8 mm 0.780 in |
| FD-BEF95 | ø9.3 mm ø0.366 in | 7.3 mm 0.287 in | 21.5 mm 0.846 in |
Cautions For Use
- Never use this product as a sensing device for personnel protection.
- In case of using sensing devices for personnel protection, use products which meet the laws and standards, such as OSHA, ANSI and IEC etc., for personnel protection applicable in each region or country.
- Firmly install the tube into the bracing arms. When installing the tube, make sure that the tube is in close contact with the sensing part. If it is not in close contact, the sensing performance may be affected.
- The tube is expected to be installed to and removed from the sensor manually approx. 3,000 times. However, periodically check the bracing arms and light intensity and replace the product if necessary.
- As water drops adhered to the sensing surface will affect the sensing performance, carefully check if dew condensation is not formed on the external surface of the tube. Also note that water drops running along the inner wall surface of the tube or bubbles adhered to the inner wall surface will affect the sensing performance.
- 耐Do not use the sensor in a place where it is exposed to water or chemicals because the sensor is neither waterproof nor chemical resistant.
- Take care that the sensor is not directly exposed to fluorescent lamp from a rapid-starter lamp, a high frequency lighting device or sunlight etc., as it may affect the sensing performance.
- Be careful not to apply excessive tensile force to the fiber part.
- Be sure to cut the fiber before installing it to the fiber amplifier.
- When inserting the fiber into the fiber amplifier, use the fiber attachment (accessory).
- Do not apply any stress (such as excessive bending or pulling) to the fiber attachment after installing the fiber to the fiber attachment.