Basic Information
Settings for up to 16 sensors can be changed at once by means of external signals
UL : Recognition
Download
Basic Information
Applications
Order guide
Specifications
Dimensions
Discontinuation plan
Last time buy (JST)
September 30, 2027
Settings for up to 16 sensors can be changed at once by means of external signals



UL : Recognition
Contact Us
The data bank setting for the digital fiber sensor FX-301B/G/H(P) and digital laser sensor LS-401(P) can be changed by using an external signal without operating the sensor. (loading / saving)
Bank settings include response times, threshold values, output operation settings, timer settings, hysteresis, stability, digital display settings (incident light intensity / percentage / peak hold / bottom hold), digital display inversion and ECO mode. These can all be changed at once using external signals to correspond to a variety of different applications.

In production lines containing target objects that vary in color from lot to lot, the fiber, sensor's settings must be changed in accordance with the characteristics of the target objects (see illustration below). However, it can be very troublesome to change sensor settings for each different arrangement or type of work. Making these changes to settings takes time and requires extra care, in order to avoid possible malfunctions. The FX-CH series allows preset bank settings to be changed, all in a single step, by utilizing an external signal, without having to handle individual sensors.
| Type | NPN input | PNP input |
|---|---|---|
| Model No. | FX-CH | FX-CH-P |
| Applicable sensors | FX-301B/G/H(P), LS-401(P) | |
| Supply voltage | 12 to 24 V DC ±10 % Ripple P-P 10 % or less | |
| Current consumption | 25 mA or less (When all indicators light up) | |
| Bank selection input | Low: 0 to 2 V DC (Source current: 0.5 mA Input impedance: 10 kΩ approx.) High: 5 V to +V DC, or open | High: 4 V to +V DC (Sink current: 0.5 to 3 mA Input impedance: 10 kΩ approx.) Low: 0 to 0.6 V DC, or open |
| Power indicator | Green LED (Lights up when the power is ON) | |
| Transmission operation indicator | Green LED (Lights up when loaded, blinks → lights up when saved) | |
| Pollution degree | 3 (Industrial environment) | |
| Ambient temperature | –10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: –20 to +70 ℃ –4 to +158 ℉ | |
| Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH | |
| EMC | EN 61000-6-2, EN 61000-6-4 | |
| Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure | |
| Insulation resistance | 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure | |
| Vibration resistance | 10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each | |
| Shock resistance | 98 m/s2 acceleration (10 G approx.) in X, Y and Z directions for fi ve times each | |
| Material | Enclosure: Heat-resistant ABS | |
| Connecting method | Connector (Note 2) | |
| Cable length | Total length up to 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. | |
| Weight | Net weight: 20 g approx., Gross weight: 25 g approx. | |
| Dimensions | W10 x H27 x D64.5 mm W0.394 x H1.063 x D2.539 in | |
| Accessory | SL-CP1 (4-pin type snap male connector): 1 pc. | |
Note 1 :Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.
Note 2 :The cable for FX-CH(-P) connection is not supplied as an accessory. Make sure to use the optional quick-connection cable given below.
Main cable (3 core): CN-73-C1 (cable length 1 m 3.281 ft), CN-73-C2 (cable length 2 m 6.562 ft), CN-73-C5 (cable length 5 m 16.404 ft)
Note 3 :Make sure that FX-CH(-P) should be mounted to a 35 mm 1.378 in width DIN rail.