SF-C14EX-01|Exclusive Control Unit for Safety Light Curtain SF-C10
Download
Discontinued
Discontinued
*Photo may vary from actual product.
This product has been confirmed that it does not contain the 6 substances specified in EU RoHS Directive 2011/65/EU and the 4 substances specified in 2015/863/EU.
| Product Number | SF-C14EX-01 |
|---|---|
| Product Number | SF-C14EX-01 |
| Product | Exclusive Control Unit for Safety Light Curtain |
| Details | Applicantion expansion unit for the SF4B series (Handy-controller non-compatible type) |
| Product Name | Exclusive Control Unit for Safety Light Curtain SF-C10 |
Spec Detail
| Item | Specifications |
|---|---|
| Part Number | SF-C14EX-01 |
| Product Number | SF-C14EX-01 |
| Product details | Applicantion expansion unit for the SF4B series (Handy-controller non-compatible type) |
| The price of the product | Please contact our office |
| Products Name | Exclusive Control Unit for Safety Light Curtain |
| Connectable safety light curtains | SF4B / SF4B-G series (Note:The handy-controller SFB-HC (optional) cannot be used with SF-C14EX-01.) |
| Applicable standards:International standard | IEC 61496-1 (Type 4), IEC 61496 (Type 4),ISO 13849-1 (Category 4, PLe) |
| CE marking directive compliance | Machinery Directive, EMC Directive, RoHS Directive |
| Control category | ISO 13849-1 (EN ISO 13849-1, JIS B 9705-1) compliance up to Category 4, PLe standards |
| Applicable standards:Japan | JIS B 9704-1 (Type 4), JIS B 9705-1 (Category 4, PLe) |
| Applicable standards:Europe | EN 55011, EN ISO 13849-1 (Category 4, PLe) |
| Applicable standards:North America | ANSI/UL 61496-1 (Type 4), UL 1998 (Class 2) |
| Power voltage | 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
| Current consumption | 0.2 A or less (Excluding Safety light curtain and other external connecting device) |
| Muting lamp output | Applicable muting lamp: 24 V DC, 3.6 to 30 W (L1, L2 of each unit) |
| Muting lamp output:Protection circuit | Incorporated |
| PFHD | 1.66 × 10-10 (Note:Probability of dangerous failure per hour) |
| MTTFD | 100 years or more (Note:Mean time to dangerous failure (in years)) |
| Environmental resistance:Degree of protection | Enclosure: IP40 Terminal: IP20 |
| Environmental resistance:Ambient temperature | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +70 ℃ -13 to +158 ℉ |
| Environmental resistance:Ambient humidity | 30 to 85 % RH, Storage: 30 to 95 % RH |
| Environmental resistance:Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| Environmental resistance:Insulation resistance | 20 MOhm , or more, with 500 V DC megger between all supply terminals connected together and enclosure |
| Environmental resistance:Vibration resistance | 10 to 55 Hz frequency, 0.35 mm 0.014 in double amplitude in X, Y and Z directions for two hours each |
| Environmental resistance:Shock resistance | 30 G acceleration in X, Y and Z directions three times each |
| Material | Enclosure: ABS |
| Connection terminal | Detachable spring-cage terminal |
| Weight | Net weight: 250 g approx. |